Guide

FOG compliance basics for Tallahassee kitchens

Plain-language FOG (fats, oils, grease) compliance basics for Tallahassee FL food service — education first, no fake certifications.

FOG programs exist so grease doesn’t coat sewer lines and cause overflows. Tallahassee-area food service businesses are typically expected to maintain interceptors, keep records, and avoid dumping grease down drains. Exact rules can vary by utility — always confirm with your local authority.

Practical habits that help

  • Dry-wipe pans before washing
  • Use sink strainers and empty them into trash
  • Schedule interceptor service before the FOG layer gets critical
  • Keep manifests or invoices from service visits

We don’t invent license numbers or claim to be the regulator. We clean traps and explain what we see so you can stay ahead of problems.

More reading: FAQ · Services · Request a quote · inspection prep.

Why FOG programs exist

Fats, oils, and grease (FOG) are liquid when they go down a hot sink and solid when they cool in a sewer pipe. Over time, they coat the inside of the pipe, narrow it, and catch debris until the line blocks. Blocked lines cause sanitary sewer overflows, which can send sewage into streets, yards, and storm drains that lead to local lakes and streams. Cities run FOG programs to keep grease out of the system at the source, which is cheaper for everyone than cleaning it out of public pipes.

Who sets the rules in Tallahassee

Several layers apply to a food service business in the Tallahassee area:

  • The Florida Building Code, Plumbing, which is based on the International Plumbing Code, sets when grease interceptors are required and how they are installed.
  • The City of Tallahassee, for businesses on City sewer, runs an industrial pretreatment program under its Sewer Use Ordinance. The City's 2020 Sewer Use Manual covers grease interceptors and sets a local limit for oil and grease in a discharge.
  • Florida Statutes section 403.0741 covers grease waste removal and the manifest that documents each pump-out.
  • Florida's Division of Hotels and Restaurants (within the Department of Business and Professional Regulation) licenses and inspects public food service establishments.
  • Outside the City, the utility that provides your sewer service, or the septic rules that apply to your property, set local requirements.

We are a service company. We do not issue permits or certificates and we are not the regulator. When a question is about what the rules require for your specific property, the City's pretreatment staff or your utility has the final word.

The main City requirements in plain language

According to the City's 2020 Sewer Use Manual, grease interceptors:

  • Must be provided when the Florida Building Code (Plumbing) requires them, or when the City decides they are needed.
  • Must be of a type and capacity the City approves.
  • Must be located so they are easy to reach for cleaning and inspection.
  • Must be inspected, cleaned, and repaired regularly by the business, at its own expense.
  • Must have a maintenance log kept on file.

The City may also require hauler manifests as reports, and it sets a local limit of 150 mg/L for total oil and grease in a discharge.

The paperwork that protects you

Good records are the easiest part of compliance to get right and the most common thing missing when there is a problem. Keep these in one binder or folder:

  1. Service manifests from every pump-out, signed and dated, showing gallons removed, the trap's condition, and the disposal facility.
  2. Your interceptor log, with dates and anything noted between visits, such as a slow drain or an odor.
  3. Repair records for baffles, lids, or plumbing work.
  4. Fryer oil recycling receipts, which show that used oil is not going down the drain.
  5. Training records, even a simple sign-off sheet showing staff were taught scraping and strainer habits.

Keep manifests for at least a year, and longer if your utility asks. Make sure an opening and a closing manager both know where the folder is.

Kitchen practices that keep you in compliance

  • Scrape plates and cookware into the trash.
  • Dry-wipe greasy pans and fryer baskets before washing.
  • Use strainers in sinks and floor drains and empty them into the trash.
  • Recycle fryer oil through a collector. Never pour it down a drain or into a storm drain.
  • Do not use enzymes, bacteria products, or chemicals to "dissolve" grease unless your utility has approved them. Many only move grease downstream.
  • Keep hot water and dish machine discharge going through the trap as designed; do not reroute fixtures to bypass it.
  • Post simple signs at the dish pit and train every new hire.

What an inspection visit looks for

Inspectors typically want to see that the interceptor is accessible, that lids open, that the unit is being maintained on a regular schedule, and that your records match. They may look at the trap itself and at downstream manholes for signs of grease. Our inspection prep guide has a checklist.

Common compliance mistakes

  • Lids buried under landscaping, dumpsters, or parked vehicles.
  • Missing or broken baffles or flow-control fittings.
  • No manifests on site, or manifests that do not show disposal.
  • Fryer oil poured into a mop sink.
  • A dishwasher or floor drain plumbed around the trap during a remodel.
  • Treating a trap that backs up with chemicals instead of service.

For maintenance that keeps your records complete, see our grease trap cleaning services in Tallahassee. Read also our permit and approval guide and pumping vs cleaning. We also serve kitchens in Perry and Madison.

A note on septic properties

Some kitchens in rural parts of Leon, Wakulla, Gadsden, and Jefferson counties are not on a public sewer. Grease is just as harmful to a septic system as to a sewer: it clogs the drainfield and shortens its life. If your kitchen is on septic, the interceptor still needs regular service, and your septic permit conditions may add requirements. Ask the county health department about your system.

FOG compliance questions

Who enforces FOG rules in Tallahassee?

For businesses on City sewer, the City of Tallahassee's industrial pretreatment program under its Sewer Use Ordinance. Florida's Division of Hotels and Restaurants licenses and inspects food service establishments, and the Florida Building Code covers plumbing.

What is the City's oil and grease limit?

The City's 2020 Sewer Use Manual sets a local limit of 150 mg/L for total oil and grease in a discharge.

How long should we keep grease trap manifests?

Keep them for at least a year, together with your interceptor log, and longer if your utility asks.

Do enzyme or bacteria products replace cleaning?

No. Many of these products only break grease into smaller droplets that move downstream and re-form in the sewer. Use them only if your utility has approved them, and keep up regular cleaning.

Schedule grease trap pumping in Tallahassee

When your kitchen is ready for service, see our restaurant grease trap cleaning and grease interceptor service in Tallahassee for what a visit includes, what affects the cost, and how manifests support City of Tallahassee FOG compliance.

Related guides

When you’re ready

Request a quote

Tell us your city, trap type if you know it, and what’s going on in the kitchen. We’ll follow up with a quote.

Request a quote

Or call (850) 999-5795

Tallahassee Grease Trap Call (850) 999-5795