Guide
Commercial kitchen grease traps in Tallahassee
Under-sink vs outdoor commercial grease traps in Tallahassee — access, capacity, and how our team quotes cleaning.
Most Tallahassee commercial kitchens use either under-sink interceptors or larger outdoor/in-ground tanks. Capacity, lid access, and traffic around the tank change how we schedule and price a visit.
Under-sink units
Common in compact cafés and food halls. Faster to service but fill quicker relative to seating if fryers run hard.
Outdoor / in-ground tanks
Serve higher volumes. Need clear lid access, safe parking for equipment, and awareness of landscaping or drive-thru lanes. Mention constraints on your quote form.
More reading: FAQ · Services · Request a quote
Which kitchens need a grease trap
Under the Florida Building Code, Plumbing, which is based on the International Plumbing Code, a grease interceptor is required for fixtures and equipment that discharge grease-laden waste in food preparation areas of places like restaurants, hotel kitchens, hospitals, school kitchens, bars, and cafeterias. Typical connected fixtures include pot sinks, pre-rinse sinks, three-compartment sinks, soup kettles, wok stations, floor drains that receive kettle drainage, and automatic hood-wash units. Inside the City of Tallahassee, the City's Sewer Use Manual adds that interceptors must also be provided when the City decides they are needed.
In practice, that covers most of the commercial kitchens we see in the Tallahassee area: restaurants of every kind, cafeterias in state office buildings, school and university dining, hospital and nursing-home kitchens, church fellowship halls, caterers and commissaries, hotel breakfast kitchens, convenience stores with hot food, and bars that serve food.
The two families of grease interceptors
Hydromechanical interceptors (HGIs)
These are the compact units, usually under or beside a sink or set into the floor. They use internal baffles and a flow-control device to slow water so grease can float and be held back. They are rated by flow (gallons per minute) and grease storage capacity (pounds), and they are tested to standards such as ASME A112.14.3 and PDI-G101. Because they hold relatively little, busy kitchens may need them cleaned every week or two.
Gravity grease interceptors (GGIs)
These are the large tanks, usually buried outside, often hundreds to more than a thousand gallons, with two or more compartments. They rely on volume and retention time rather than mechanical baffles. They hold more grease, so they are usually pumped on a monthly to quarterly cycle. They need clear access for a vacuum truck and planning around parking and traffic.
There are also automatic grease removal devices that skim grease on a timer into a container. They still need their containers emptied, their solids basket cleaned, and periodic full cleaning.
How to find out what you have
- Look under and around the dish pit and the three-compartment sink for a metal or plastic box with a lid, often with bolts or clamps.
- Look outside for round or rectangular lids, usually concrete or cast iron, in the parking lot, a landscaped strip, or near the back door. There are often two or more in a line.
- Check your lease, building plans, or past invoices for the size.
- Ask the landlord or property manager, especially in multi-tenant centers where several kitchens may share one interceptor.
If you are not sure, tell us what you see and send a photo of the lids. We can confirm on the first visit.
Good practice for every kitchen
| Area | What to do |
|---|---|
| Dish pit | Scrape plates into the trash; use a strainer in every sink compartment |
| Prep line | Wipe pans and sheet trays with paper towels before washing |
| Fryers | Collect used oil for a recycler; never drain it into a sink or floor drain |
| Floor drains | Keep strainers in place; sweep before mopping |
| Mop sink | Do not dump fryer oil, grease, or food solids |
| Disposals | Keep food solids out of disposals that drain to the trap |
| Hood filters | Scrape grease off filters before washing them in the sink |
| Training | Teach every new hire on day one; post signs at the sink |
Shared interceptors in multi-tenant buildings
Shopping centers along Apalachee Parkway, Capital Circle, and North Monroe Street often have several food tenants. Sometimes each has its own trap; sometimes several kitchens drain to one large interceptor. With a shared unit, agree in writing on who schedules service, who pays, and who keeps the records. If one tenant adds a fryer or extends hours, the shared interceptor fills faster for everyone. We can work with the property manager on one schedule and provide manifests each tenant can keep on file.
Institutional kitchens
School, university, hospital, and government kitchens tend to have large interceptors and predictable calendars. The challenge is usually access and scheduling around security, deliveries, and meal times. Campus kitchens see big swings between semesters and summer. A schedule that tightens during peak periods and relaxes in quiet stretches, based on measured layers, keeps costs reasonable without risking overflows.
Signs the trap is not keeping up
- Slow drains at the dish pit during rush.
- Grease odors indoors or near the outside lids.
- Water backing up into floor drains when the dish machine dumps.
- Measured layers at or above about a quarter of liquid depth at each visit.
- Grease visible downstream at a cleanout or manhole.
When you see these, see our clogged grease trap signs guide and our size and capacity guide.
For pricing and recurring service, see our grease trap cleaning services in Tallahassee. We serve kitchens across Leon County and nearby towns such as Quincy and Woodville.
What to tell us when you request service
Your business name and address, the type of kitchen, whether the trap is under a sink or outside, its size if known, how often it is serviced now, and any recent problems such as slow drains or odors. Photos of the lids help us bring the right equipment the first time.
Commercial kitchen trap questions
Does every commercial kitchen in Tallahassee need a grease trap?
Most do. The Florida Building Code requires grease interceptors for fixtures that discharge grease-laden waste in food preparation areas, and the City of Tallahassee can also require one when it decides it is needed. Confirm with your plumbing official or utility.
What is the difference between a hydromechanical and a gravity grease interceptor?
Hydromechanical units are compact and use baffles and a flow control to separate grease; they need frequent cleaning. Gravity interceptors are large outdoor tanks that rely on volume and retention time and are usually pumped monthly to quarterly.
Who is responsible for a shared grease interceptor?
It depends on the lease. Agree in writing with the landlord and other tenants on who schedules service, who pays, and who keeps the records.
Can a commercial kitchen use an automatic grease removal device?
They are allowed in many settings, but they still need their grease containers emptied, solids baskets cleaned, and periodic full cleaning.
Schedule grease trap pumping in Tallahassee
When your kitchen is ready for service, see our restaurant grease trap cleaning and grease interceptor service in Tallahassee for what a visit includes, what affects the cost, and how manifests support City of Tallahassee FOG compliance.
Related guides
When you’re ready
Request a quote
Tell us your city, trap type if you know it, and what’s going on in the kitchen. We’ll follow up with a quote.
Request a quoteOr call (850) 999-5795